• original pneumatic smc factory new

    What is a post tension slab? How to tell if a home has a

    A post tension slab is a concrete slab that has steel cables running through it that have been placed under 33,000 +/- pounds of tension. This tension makes the concrete slab and foundation much stronger than concrete without reinforcement and helps reduce cracking.

  • hydraulic cylinder used for engineering machinery

    Question of anchoring gunsafe to post tension slab - …

    Mar 31, 2012· Question of anchoring gunsafe to post tension slab General Gun ... Do you have as builts or the structural drawings showing where the post tension cables are? How thick is the slab? How deep do you plan to drill? ... In a lot of cases you can look around the perimeter of the slab on the exterior and see the indentions/cups where the cable is ...

  • self-locking hydraulic jack

    VSL | Stay cable systems - Post-tensioning

    Home Business Lines SYSTEMS & TECHNOLOGIES STAY CABLE SYSTEMS. ... Applying the strand / wedge anchorage principles of VSL’s post-tensioning systems, VSL stay cables have a long and successful track record culminating in the most recent SSI 2000 range with its anchorages, saddles and dampers. ... This renders the cable installation largely ...

  • rodless cylinder AW40-06-A smc air regulator

    Finding tension cable in foundation | Fine Homebuilding

    Aug 19, 2002· I need to install a floor safe in a concrete slab that has tension cables running through it. What method(s) are there to find where they are. ... "Finding tension cable in foundation" ... The post tension cables are about 3/4" dia sheathed in a plastic sleeve...looks very much like an oversized stranded electrical wire. ...

  • tension jack

    Cable Loads - Engineering ToolBox

    TENNIS COURT POST-TENSION CONCRETE SLAB DO’S & DON’TS. THE DO’S AND DON’TS ... • Post-tension cables • Key Joint • Expansion joint with cap • Isolating posts, fence, bench, shade structure, sleeves ... CASE STUDY OF RESTRAINED POST TENSION CABLE TENNIS COURT CONCRETE SLAB OVERLAY

  • 100T hydraulic cylinder jack

    Pretension in Wire Cable Wall - Structural engineering

    Force and tension in cables with uniform loads. ... Cable Loads Force and tension in cables with uniform loads . Sponsored Links . Uniformly Loaded Cables with Horizontal Loads. ... h = cable sag (ft, m) mass and weight ; The vertical support forces at the end of the cable can be calculated as.

  • construction machinery telescopic hydraulic lift

    Problems with cutting Post Tension Cable concrete slabs …

    www.tensacciai.it Post-tensioning. Tensacciai started to operate in the field of ... information regarding post-tensionig tendons made of strands 15,7 (0,6”S) or 15,2 mm (0,6”) diameter. ... and allows installation of cables in different separate stages. MTAI system, with its compact geometry and

  • dump truck hydraulic hoist

    Ready Cable Inc.

    actually weight will have a small affect ... the lateral defliection due to lateral wing loads will move the CG off the axis of the cable, creating a small moment in the cable (increasing the tension in the upper 1/2, reducing it in the lower 1/2).

  • mortar pump double cylinder

    Post Tensioning Installation Equipment - Williams Form

    • Cable Trays and Strut • Utilities • Pipe Supports ... post-tensioned cables. Blow the hole clean of dust and other materials. Insert ... Edge Distance, Tension (F nc) (Normal-weight concrete only) Dia. (in.) 1/4 3/8 1/2 c cr (in.) 3 4-1/2 6 c min (in.) 1-1/2 2-1/4 3

  • Triplex Piston Single-Acting Mud Pump (BW-150)

    Top 10 Biggest Mistakes Made in Post-Tensioned Concrete

    Top: Post-tensioning tendons are draped within the slab cross section. Bottom: Significant over-balancing of the weight of the concrete with post-tensioning can actually lift and crack the slab. The inspector and the contractor must verify that the layout conforms to the

  • single acting hole jack

    Wire and Cable Pulling Tensions - Southwire

    This paper outlines the major advantages of the use of post-tensioning in building structures. Economics of the post-tensioning slab system are ... using light weight jacking equipment. Figure 2 shows the cast iron anchorage guide, ... Post-tensioned concrete slabs in buildings have many advantages over reinforced concrete

  • KIET P-392 Hydraulic Pump Hydraulic Hand Pump

    Post Tension Cable Location Services Queensland & NSW

    SUGGESTIONS FOR INSTALLATION OF THE MONTROSE MODEL WITH SCREEN AREA 1.0 MEASUREMENTS A. Building ... Once sections are aligned run post-tension cables (provided) through the holes cast into the floor. ... Leave cables at tension. Cut off excess cable length and grout over holes. Use caulk provided to seal building section walls and roof where ...

  • DC12V 24V tipper trailer Power Unit

    Post Tension Cable failure - InterNACHI Inspection Forum

    Post tension cable slabs are extremely beneficial to help combat the effects of our soil conditions in Southern California. Cutting cables – The cables installed are usually pulled so they each have approximately 28,500 lbs. of tension.

  • pneumatic rotary actuator AER25-03-A air solenoid valve

    Bridge Cable | TMG - Post Tensioning System

    Ready Cable engineers and fabricates rebar and post tension cables. We also stock fabricated rebar, stock rebar, lumber and foundation accessories.

  • construction machinery telescopic hydraulic lift

    Post-tensioned Foundation Information That Every …

    This paper describes the assessment of the bridge cables, examines the consequences of a cable ... Post-tensioned transverse floor beams, 3.0m centre to centre longitudinally, connect the edge girders and support ... • Installation of longitudinal prestress in the deck slab at midspan

  • hydraulic cylinder

    Tensioned Cable Hardware Install | Nixalite

    Williams Form Engineering Corporation's Post Tensioning System Installation Equipment; such as grout pumps, hydraullic jacks and torque wrenches. ... ACCESSORIES DIVISION . Post Tensioning Installation Equipment. Post Tension Information: Parts & Accessories: Post Tension Installation: Installation Equipment ... Weight of Ram & Frame: 60 tons ...

  • WORKING PRESSURE 35 Mpa Double Acting 50 ton hydraulic cylinder

    Services | Chematics Restoration

    Installation- Cheyenne 1 DocS.2 Rev.0 CXT INCORPORATED SPOKANE, WASHINGTON SUGGESTIONS FOR INSTALLATION OF THE CHEYENNE MODEL 1.0 MEASUREMENTS A. Building Floor Dimensions: 0’5” in height, 26’0” in width, 30’0” in length ... Once sections are aligned run post-tension cables (provided) through the holes cast into the floor and roof ...

  • pneumatic valve AW30-02-A smc internet

    Post-Tension Concrete - Info session for Contractors

    Top 10 Biggest Mistakes Made in Post-Tensioned Concrete Design ... January 20, 2016. After decades of building and inspecting in the Post-Tensioning (PT) concrete construction industry, we’ve seen the best and the worst of PT construction. ... and with flat plates where long term deflections may affect window installation. 3D software will ...

  • pneumatic valve AFD40-06-A solenoid valve 5v dc

    Wire and Cable Pulling Tensions Cable damaged during installation can cause service failures. Calculations should be made to indicate whether the pull looks easy or impossible.

  • pneumatic solenoid valve AFM40-06-A 12v solenoid valve

    dead weight removed, the long term defl ection multipliers of 3 to 5 are irrelevant, since the ... ommon Post-Tensioning C & onstruction Issues By Bryan Allred, S.E. Figure 2: Slip provided by plastic placed over ... Stay Cable Testing Supply and Installation System 100 - FDOT compliance pending www.dsiamerica.com

  • pneumatic valve AW30-02-A smc internet

    protected stay-cable strands and very high tensile steels. ... • Deviated tension is current in post-tensioned structures, stay-cables and even some prefabrication methods. By strict adherence ... weight Nominal steel area Minimum breaking strength Yield strength minimum load

  • hydraulic ram jack

    A post tension cable is a key support for concrete construction. It allows builders to use thinner slabs of concrete but still support the same amount of weight. These cables also make it possible to use fewer support columns.

  • Large steel forged telescopic hydraulic ram

    Apr 18, 2008· Post Tension Cable failure I arrived within minutes and was led to a corner unit on the 2nd floor. Once inside I observed a hole in the ceiling about 5 inches in diameter and 1 inch deep.

  • hydraulic jack model

    TECHNICAL SESSION 4 Post-Tensioned & Cable Stayed Bridges Moderator John Crigler VSL Hanover, MC

  • pneumatic linear actuator CHKDB100R-200 solenoid valve

    Cable Stayed Bridge is a kind of bridge formed by the combination of tower and bridge cable, to support the deck of the bridge. Its structure is developed through the load bearing of the tower, tension of the bridge cable and the bending of the deck beam.

  • construction machinery telescopic hydraulic lift

    Repairing a Post-Tension Anchor By Stephen A. Johanson B ... that slides out and allows installation over the post-tension cable. A set screw secures this section in location. Split wedges are placed over the cable ... Nominal weight/mass 0.52 lbs/ft 0.78 kg/m Yield strength 37.2 kips 165.3 kN Min. breaking load 41.3 kips 183.7 kN

  • To Bangladesh hydraulic jack

    A post-tensioned foundation is a concrete slab foundation that is reinforced with steel cables that are tensioned after the concrete hardens. The stranded cables are slid inside of plastic-sheathing, which prevents the steel tendons from touching the concrete.

  • original pneumatic smc mould factory new

    Bird Netting Tensioned Cable Hardware Installation instructions. Call us: 888-624-1189 / 309-755-8771. Free product catalog! ... Installing Cable Hardware for Bird Netting ... Install support cables if needed for interior support for the netting.

  • hydraulic cylinder for construction machinery

    Chematics Restoration Engineering Services. ... The design of PT cables creates a slab that can support more weight without having to add additional columns. Once installed, the PT cables are tensioned prior to removal of the forms during original construction. ... Installation of post tension cables; Architectural Coatings.

  • heavy duty telescopic hydraulic cyinders

    Post-Tension Concrete - Info session for Contractors ... Post-Tension Concrete - Info session for Contractors 1. ... 6.1 PTI Field Procedures Manual Published by Post- Tensioning Institute Provides procedures and details for post- tensioned concrete installation. Introduction Document Control Delivery, Acceptance, Handling and Storage ...

Our Factory

Founded in 2012, Gaode Equipment Co., Ltd. (short:“Gaodetec”) owns the most advanced imported production equipment and complete production technology...

Read More

Factory Gallery

Contact Us